25% OFF MEGASALE EVENT!

Valid only on all Compresstome® VF-310-0Z and VF-210-0Z vibrating microtomes

 

Promotion Ends June 30, 2020

 

25% OFF MEGASALE EVENT!

Valid only on all Compresstome® VF-310-0Z and VF-210-0Z vibrating microtomes

 

Promotion Ends June 30, 2020

 

Find Out More

Get A Quote

*Does not include purchases from the following countries: Those under China and Japan.
*Valid only for VF-310-0Z, and VF-210-0Z sales. Does not include additional accessory purchases.

JOVE Videos Featuring the Compresstome Vibrating Microtome

We’re proud to announce that our line of Compresstome vibrating microtomes have been used and featured in multiple JOVE scientific and educational videos! Here, we want to introduce you to the key videos showing our tissue slicers in action.

Please enjoy the JOVE videos below showing how researchers have used the Compresstome in their experiments. The footage provides a first-hand look at the embedding process as well as seeing the Compresstome make cuts.

1. Combining Lipophilic dye, in situ Hybridization, Immunohistochemistry, and Histology

Compresstome® slicers are designed for achieving rapid cutting of high-quality free-floating sections for optimal immunohistochemistry. Researchers at the University of Iowa injected lipophilic dye in mouse models for in situ hybridization, immunohistochemistry, and histology experiments. Agarose embedding stabilizes the tissue during sectioning and diminishes the amount of dye leakage as seen with frozen tissue sectioning. Serial sections of whole brain tissue are obtained using Compresstome VF-700-0Z and allow for visualization of regions of interest.

JOVE Videos_Figure 1

Figure 1. Lipophilic dye placement and imaging in a mouse embryo hindbrain that has been dissected and flat mounted. The trigeminal nerve is labeled with NeroVue, Red, the glossopharyngeal nerve: NeuroVue, Maroon, and vagus nerve: NeuroVue Jade.

VF-700-0Z_JOVE Videos_Figure 2

Figure 2 Compresstome VF-700-0Z vibrating microtome designed to section fixed tissue for immunohistochemistry experiments.

2. Genetic Manipulation of the Mouse Developing Hypothalamus through In utero Electroporation

Researchers have used the Compresstome VF-300-0Z in their procedure to section mouse embryo hypothalamus that has been injected with DNA and electroporated. This procedure demonstrates how it is possible to transfect nuclei in the hypothalamus region which are less accessible than those in superficial regions. Following this procedure additional experiments can be performed such as immunohistochemistry and in situ hybridization.

Figure 3. A lab member retrieves free floating sections from the buffer tank of Compresstome VF-300-0Z.

3. In Situ MHC-tetramer Staining & Quantitative Analysis of Antigen-specific CD8 T Cells in Tissues

Fresh tissue can vary wildly in its level of difficulty to cut, due to a variety of factors like tissue type, and maturity of the animal (myelination). Often with other vibrating microtomes, they struggle to handle highly myelinated tissue or very soft neonatal tissue. The compression effect, along with multiple points of adjustment (Speed, oscillation, and agarose concentration) enables our instrument to better handle “difficult” to cut tissue. The Compresstome isn’t just able to cut thinner than the competition, we believe that the evidence shows that we also provide higher quality cuts that preserve cell surface structures and help increase the number of healthy to dead cells. Researchers at University of Minnesota use a Compresstome VF-300-0Z to section live tissue in their procedure to locate, quantify, and phenotype antigen-specific CD8 T cells.

Figure 4. The buffer tank of Compresstome VF-300-0Z is filled with PBSH buffer and PBSH ice cubes are added to increase the longevity of the live tissue sections that will be made.

4. A Rapid Approach to High-Resolution Fluorescence Imaging in Semi-Thick Brain Slices

The footage above shows how neuroscientists use the Compresstome VF-300-0Z tissue slicer to obtain brain slices for imaging studies. When using the Compresstome tissue is embedded inside one of the specimen tubes. The specimen tube is made of two pieces: the inner plastic plunger and the outer metal tube. The inner plastic plunger is where you will mount your sample. The plunger is drawn down so much that there is approximately 5cm of length for your tissue sample to be embedded inside the metal tube. Compresstome VF-200, VF-200-0Z, VF-210-0Z, VF-300, VF-300-0Z, and VF-310-0Z all use this embedding procedure. Please visit our website to learn more about our unique tissue slicers.

Figure 5. A chilling block is held around the Compresstome specimen tube to solidify the liquid agarose around the tissue sample.

5. Preparation of Acute Brain Slices Using an Optimized N-Methyl-D-glucamine Protective Recovery Method

Often heralded as leaders in the field, the Allen Brain institute performs pioneering research on all manner of brain tissue. Working with brain tissue can often be as frustrating as it is rewarding. Slicing brain tissue presents many challenges. The tissue is a combination of soft and fibrous regions. For over a decade, researchers at the Allen Institute for Brain Science have been using the Compresstome VF-200 vibrating microtome to help give them better brain slices with increased longevity and reduced damage to surface neurons. This enables neuroscientists to have healthy neurons for patch-clamp.

Figure 6. The specimen tube is inserted into the buffer tray of Compresstome VF-200 prior to sectioning.

6. Immunology and Infection: The Compresstome® for Precision-Cut Lung Slices

The Compresstome® has been widely used by researchers worldwide for making Precision-Cut lung slices (PCLS). The Compresstome® uses agarose embedding prior to slicing to allow for the preservation of open alveoli and better tissue compliance. The video above shows Compresstome VF-300 sectioning PCLS for immunostaining to visualize the localization of various immune cell types in the lung. This protocol can be extended to visualize the location and function of many different cell types under a variety of conditions.

Figure 6. The specimen tube is inserted into the buffer tray of Compresstome VF-200 prior to sectioning.

Feel free to contact us, we will be happy to hear from you!

Leave a Reply

Your email address will not be published. Required fields are marked *